Untitled Document
 Modules Overview  
 
 Assistance  
 FAQs  
 Agilent 16900 Systems  
 Benchtop Models  
 Agilent Web Site  

Overview - 16900-series Logic Analysis Modules

Getting there just got easier
Agilent logic analyzer modules offer the speed, features, and usability your digital development team needs to quickly debug, validate, and optimize your digital system at a price that fits your budget.

Modularity is the key to the Agilent 16900 Series logic analysis systems’ long term value. Purchase only the capability you need now, then expand as your needs evolve. All modules are tightly integrated to provide time-correlated, cross-domain measurements.

Customize your system with the measurement capability that will meet your performance and price needs. Protect your investment by upgrading logic analyzer module memory depths or state speeds as your needs change.

    16740-16741-16742A
    16750-16751-16752A
    16753-16754-16755-16756A
    16910 & 16911
    16950

Intel 1 GHz processor with 512 MB of RAM

Up to 510 acquisition channels with the new 16910A module (16900A, 16902A) or 306 acquisition channels (16903A)

Common interface, toolsets and protocol decode software with 1680 / 1690 series benchtop logic analyzers

A 15 GB hard drive and multiple I/O ports provide several options for data storage, retrieval and sharing.

 16900, 16902 and 16903 Logic Analyzer Modules:
Feature
16740
16750A
16753A
16910
16950
Channels Available, 1 time base (note 4) 340 340 340 510 340
Maximum State Speed MHz (note 2) 200 400 600 450 600
Max.Conventional Timing, full channel MHz (note 3) 400 400 600 400 1200
Max.Conventional Timing, half channel MHz (note 3) 800 800 1200 800 1200
Maximum Transitional Timing 400 400 600 N/A N/A
Data Acquisition Memory (Note 1) 1MB 4MB 1MB 4MB 1MB
Data Valid Window 1.25 ns 1.25 ns 1 ns TBD 1 ns

Note 1 (for 16740A):
The 16740A has 1 MB; the 16741A has 4 MB; the 16742A has 16 MB.

Note 1 (for 16750A):
The 16750A has 4 MB; the 16751A has 16 MB; the 16752A has 32 MB.

Note 1 (for 16753A):
The 16753A has 1 MB; the 16754A has 4 MB; the 16755A has 16 MB, and the 16756A has 64 MB.

Note 2 (for 16750A, 753A, 910A, 950A):
State speeds listed require a trade-off in features. Contact Agilent for details.

Note 3 (for 16750A, 16751A, 752A, 760A):
These analyzers also have 2 GHz Timing Zoom. Contact Agilent for details.

Note 3 (for 16753A, 16754A, 16755A, 16756A):
These analyzers also have 4 GHz Timing Zoom. Contact Agilent for details.

Note 4 (for 16910, 16911):
The 16910 has 510 channels available, the 16911 has 340.

 

FS4410 Product Image
Agilent 16910 & 16911
FS4410 Product Image
Agilent 16950

Agilent 16900 Series