Specifications - FS4410 SRIO Protocol Analysis Probe
For use with Agilent Logic Analyzers
Data acquisition in 8b Decoded Data mode at 3.125, 2.5 or 1.25 Gbps (reference clock recommended)
Reference clock frequencies:
1.25 Gbps is supported with an external reference clock of 62.5 MHz (x20 ref)
2.5 Gbps is supported with an external ref clock of 125 MHz (x20 ref) or 100 MHz (x25 ref as done in PCIe)
3.125 G is supported with an external ref clock of 156.25 MHz (x20 ref)
Lane modes: x1 lane and x4 lane (able to select x1 probing on lane 0 or lane 2).
Lane deskew (align) in x4 lane mode.
Supports debug of physical, transport and logical layers (messaging, I/O and streaming
Detects, displays, filters in/out, and allows triggering on the following events in 8b Decoded Data Mode:
Silence
Invalid serial byte (code violation or disparity error detected, but not displayed)
Idle Sequence
Control Symbols with Stype0 and Stype1
Control Symbols within packets
Packet Types 0 through 15
Packet Spreading of x1 link data to 4 column format
FS4411 is available to add PCI Express analysis capability. Switching between the two is accomplished via the Probe Manager Software.
Power Requirement - +5V DC (external supply included)
USB connector for probe control from a PC
FS4410 Serial RapidIO Protocol Analysis Probe