Untitled Document
|
System Requirements
- FS4120 Universal Serial Bus (USB2.0) Analysis Probe
- For protocol decode, the FS4120 requires 2 logic analyzer pods for
1.1 OR 2.0 modes.
- For timing observation of the serial bit stream in 1.1 mode only,
an additional pod is required
- The FS4120 does not require Termination Adapters.
- A logic analyzer pod has 17 channels.
- USB 1.1 Protocol Decode and Timing Analysis - This configuration
is used by the FS/LS channel only on a single logic analyzer card.
This configuration provides both protocol decode (2 pods required)
and timing analysis (an additional pod is required) with one logic
analyzer card.
- USB 1.1 and 2.0 Protocol Decode - This configuration is used
by the HS/FS channel and the FS/LS channel. This configuration provides
protocol decode (2 pods required) for both channels. In other words,
you can simultaneously analyze protocol traffic on a HS/FS connection
and a FS/LS connection with one logic analyzer card.
- USB 1.1 Protocol Decode and Timing Analysis and USB 2.0 Protocol
Decode - This configuration is used by the HS/FS channel and
the FS/LS channel. This configuration provides protocol decode (2
cards and 5 pods required) for the HS/FS channel and timing analysis
(1 pod required) for the FS/LS channel. In other words, you can simultaneously
analyze protocol traffic on a HS/FS connection and do timing analysis
on a FS/LS connection with two logic analyzer cards.
- Click
Here for information on Off Line Analysis support for this product
- We recommend you use the latest Agilent operating
software to insure you will get the best performance from FuturePlus
products. To get the latest 1680/1690/16900 logic analyzer software click
here.
Benchtop Logic Analyzers
| 1680/1690 Analyzers |
Description |
Pods Available
|
| 1680A |
200 MHz State/400 MHz Timing |
8 |
| 1681A |
200 MHz State/400 MHz Timing |
6 |
| 1682A |
200 MHz State/400 MHz Timing |
4 |
| 1690A |
200 MHz State/400 MHz Timing |
8 |
| 1691A |
200 MHz State/400 MHz Timing |
6 |
| 1692A |
200 MHz State/400 MHz Timing |
4 |
16800 series Analyzers
|
16800 series
Analyzers
|
Description
|
Pods Available
|
| 16801A |
250 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
2 |
| 16801A turbo |
500 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
lose one pod per machine |
| 16802A |
250 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
4 |
| 16802A turbo |
500 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
lose one pod per machine |
| 16803A |
250 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
6 |
| 16803A turbo |
500 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
lose one pod per machine |
| 16804A |
250 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
8 |
| 16804A turbo |
500 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
lose one pod per machine |
| 16806A |
250 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
12 |
| 16806A turbo |
500 Mb/s State/1 GHz Timing, 4 GHz Timing Zoom |
lose one pod per machine |
Logic Analysis Systems
|
16900/902/903
Modules
|
Description
|
Pods Available
|
| 16740-741-742A |
200 MHz State/400 MHz Timing, 2 GHz Timing Zoom |
4 |
| 16750-751-752A |
400 MHz State/400 MHz Timing, 2 GHz Timing Zoom |
4 |
| 16910A |
250 MHz State/1.2 GHz Timing, 4 GHz Timing
Zoom |
6 |
| 16910A in turbo mode |
450 MHz State/1.2 GHz Timing, 4 GHz Timing
Zoom |
lose one pod per machine |
| 16911A |
250 MHz State/1.2 GHz Timing, 4 GHz Timing
Zoom |
4 |
| 16911A in turbo mode |
450 MHz State/1.2 GHz Timing, 4 GHz Timing
Zoom |
lose one pod per machine |
|
 |
 |
FS4120 USB2.0
Analysis
Probe |
|
|