You may not have enough logic analyzer cards to meet the System Requirements.
Can you still do useful analysis? The answer is yes. Table
1 shows just what protocol analysis you can do with various card
configurations. Table
2 shows just what timing analysis you can do with various card configurations.
Table 1 -
FS2331 Protocol Analysis With Various Card Configurations
DDR1 Memory Bus Speed
Modules Supported
3 cards configured as two state analysis
machines
2 cards configured as two state analysis
machines
1 card configured as one state analysis
machine
200 MT/s (PC1600)
16750/751/752
16753/754/755/756
16910/911
16950
State capture
of Cmd + Read AND Writes
State capture of Cmd + Read AND Writes
State capture of Cmd bus
333 MT/s (PC2700)
16753/754/755/756
16950
State
capture of Cmd + Read AND Writes
State capture of Cmd +
Read OR Writes
State capture of Cmd bus
Table 2 - FS2331