Frequently Asked Questions -- Which Agilent Logic Analyzer Should I Use?
Agilent has two main families of logic analyzers - the benchtop
or portable products, and the mainframe Logic Analysis Systems.
There are two types of mainframes, the older 16700 series
and the new 16900 series.
Knowing which is best for you is something you should discuss in detail
with your Agilent Sales Engineer.
For details, you may click the link at the left to
go directly to the Agilent web site. However, we have summarized the
different families below for your quick reference.
16800 Series Benchtop Logic Analyzers
Feature
16801
16802
16803
16804
16806
Channels Available
34
68
102
134
204
Pods Available
2
4
6
8
12
Maximum State Speed (note 1)
250 mB/S
250 mB/S
250 mB/S
250 mB/S
250 mB/S
Max.Timing Speed (Note 2)
1 GHz
1 GHz
1 GHz
1 GHz
1 GHz
State Data Acquisition
Memory (Note 3)
1 M
1 M
1 M
1 M
1 M
Note 1:
450 MHz/500 Mb/s (opt 500) available Note 2:
4 GHz Timing Zoom standard
Note 3:
4 MB, 16 MB and 32 MB options available Note 4:
Touch Screen option (opt 103) available
B4600A - System Performance Analysis Software for 16505A
B4620A - Software Analyzer Software for 16505A
The Agilent E2479A Upgrade Kit will upgrade any 16500A or 16500B to a
16500C. The 16500C still supports any measurement module ever made for
the 16500 series.
16500B/C Logic Analyzer Modules:
Feature
16550A
16554A
16555A
16556A
Channels Available,
One time base
102-204
68-204
68-204
68-340
Pods Available, One time base
6-12
4-12
4-12
4-20
Maximum State Speed
100 MHz
70 MHz
110 MHz
100 MHz
Maximum Conventional Timing, full channel
250 MHz
125 MHz
250 MHz
200 MHz
Maximum Conventional
Timing, half channel
500 MHz
250 MHz
500 MHz
400 MHz
Maximum Transitional Timing, full channel
125 MHz
N/A
N/A
N/A
Maximum Transitional
Timing, half channel
250 MHz
N/A
N/A
N/A
Data Acquisition Memory (Note 1)
4KB
500KB
1MB
1MB
Note 1 (for 16550A): 4K, all channels; 8K half channels
Note 1 (for 16554A,555A,556A): Available memory doubles in half channel
mode for timing mode only. The 16555D and 16556D models provide 2 MB memory
standard.
Other Modules for the 16500B include:
16517A- 4 GSa/s, 16-ch, 64KB Timing analyzer
16518A 4 GSa/s, 16-ch, 64KB Timing analyzer expansion for 16517A
Note 1 (for 16554A,555A,556A):
Available memory doubles in half channel mode for timing mode only. The 16555D
and 16556D models provide 2 MB memory standard.
Note 1 (for 16715A, 16716A, 16717A):
Available memory doubles in half channel mode for timing analysis only.
Note 1 (for 16710A):
The 16710A has 8KB; the 16711A has 32 KB; the 16712A has 128KB.
Note 1 (for 16715A):
The 16715A has 2MB; the 16716A has 512 KB.
Note 1 (for 16717A):
The 16717A has 2 MB; the 16718A has 8 MB; the 16719A has 32 MB.
Note 2 (for 16717A, 718A, 719A):
State speeds greater than 167 MHz require a trade-off in features. Contact
Agilent for details.
Note 3 (for 16716A, 16717A, 718A, 719A):
These analyzers also have 2 GHz Timing Zoom. Contact Agilent for details.
16900, 16902 and 16903 Logic Analysis Systems
Standard features for the 16900, 16902 and 16903 include:
Six module slots (the 16903 has three)
RS-232 and IEEE-488 interfaces
16900 requires external display, 16902 and 16903 include color
flat-panel touch screen display
1.44 MB DOS-compatible floppy disk drive
4 GByte hard disk drive
Mouse
Ethertwist 10Base Interface (RJ45 connector)
ThinLAN 10Base2 Interface (coax connector)
Centronics printer port
PS/2 keyboard and mouse connectors
Target Control Port
E2450A - Symbol Download Utility Software
10390A - System Performance Analysis Software
B4600A - System Performance Analysis Software
B4620A - Software Analyzer Software
The 16900, 16902 and 16903 support some but not all of the measurement
modules made for the 16700 series. Contact your Agilent Sales Office
for details.
16900, 16902 and 16903 Current Logic Analyzer Modules:
Feature
16740
16750A
16753A
16910
16950
Channels Available, 1 time base (note
4)
340
340
340
510
340
Maximum State Speed MHz (note 2)
200
400
600
450
600
Max.Conventional Timing, full channel
MHz (note 3)