System Requirements - FS2338 & FS2343 FBD Channel Analysis Probes
Agilent 16900-series Logic Analysis Systems
- See the table below for FS2338 and FS2343 protocol analysis requirements.
- The FS2338 and FS2343 make connection and termination to the logic analyzer with the E5378A Termination Adapter. Up to 5 are required.
- The FS2338 and FS2343 FBDIMM Probes requires up to five logic analyzer cards depending on what decode information is required by the user. There are several different configuration files provided for the applications shown in the table below. Note: all these configurations require the use of 16753/4/5/6 or 16950 cards and Dual Sample Mode in the Logic Analyzer.
- A logic analyzer pod has 17 channels
- Click Here for information on Off Line Analysis support for this product
- We recommend you use the latest Agilent operating software to insure you will get the best performance from FuturePlus products. To get the latest 1680/1690/16900 logic analyzer software click here.
Agilent 16900-series Configurations
|
High Speed Channel
|
Analyzer Type
|
Probe Configuration
|
Protocol Analysis
(with up to 4 GHz Timing Zoom) |
|
4.8 Gb/s |
16753/754/755/756 |
10 lane SB with 8 Trigger bits |
3 cards configured as one module, one dual sample state machine |
|
4.8 Gb/s |
16753/754/755/756 |
14 lane NB with 9 Trigger bits |
4 cards configured as one module, one dual sample state machine |
|
4.8 Gb/s |
16753/754/755/756 |
14 lane NB and 10 lane SB with 5 Trigger bits |
5 cards configured as one module, one dual sample state machine |
|
4.8 Gb/s |
16753/754/755/756 |
12 lane NB and 10 lane SB with 10 Trigger bits |
5 cards configured as one module, one dual sample state machine |
Agilent 16900-series Modules
|
16900/902/903 Modules
|
Description
|
Pods Available
|
| 16753-756A dual sample | 800 Mb/s State/1.2 GHz Timing, 4 GHz Timing Zoom | 2 |
|
16950A dual sample
|
800 Mb/s State/1.2 GHz Timing, 4 GHz Timing Zoom | 2 |